Inner Banner

Our
Products

We give residential and commercial services for:

  • Single phase and Three phase Electrical wiring.
  • Install and repair all type of Appliances and equipment's.
  • Good work on power line distribution panel etc.

Automatic Generator Changeover

Send Inquiry

YOUR ARE HERE : hm> Automatic Generator Changeover

Enlisted amidst the most trusted name in this domain, we are a reckoned for the exceptional quality and certified Automatic Generator Changeover. We are headquartered in Sangrur, Punjab, India, offering the best in class and experts’ certified array of Automatic Single Phase Changeover that is designed under the vigil supervision of experts and veteran professionals. We are capable enough of delivering Single Phase Automatic Changeover that is performance oriented and is sternly examined by the Engineers. The Automatic Generator Changeover we make available is affordable and delivered in the set time.

Salient Features –

  • It transfers the load between main line and generator automatically so there is no need of physical operation.
  • It will release generator supply after 10 sec. time delay. It helps to prevent heavy load on diesel engine during start up.
  • When power come back load will transfer instantly from generator to main supply.
  • LED Indication for Main line and generator supply.

SINGLE PHASE CHANGEOVER

32 Amp. Single Phase

Product code:- S-11
Working Voltage:- 230 V. 50hz.
Minimum operating voltage:- 145 V. ± 4%
Connection Terminal:- 6-way. Generator (N-P), Load(N-P), Main line(N-P)
Dimensions in (mm):-
W-205, H-165, D-105

63 Amp. Single Phase

Product code:- S-13
Working Voltage:- 230 V. 50hz.
Minimum operating voltage:- 145 V. ± 4%
Connection Terminal:- 6-way. Generator (N-P), Load(N-P), Main line(N-P)
Dimensions in (mm):-
W-255, H-180, D-105

100 Amp. Single Phase

Product code:- S-14
Working Voltage:- 230 V. 50hz.
Minimum operating voltage:- 145 V. ± 4%
Connection Terminal:- 6-way. Generator (N-P), Load(N-P), Main line(N-P)
Dimensions in (mm):-
W-305, H-250, D105

THREE PHASE CHANGEOVER

63 Amp. Three Phase (TPN)

Product code:- T-21
Working Voltage:- 415 V. 50hz.
Minimum operating voltage on generator supply:- 145 V. ± 4%
Connection Terminal:- 12-way. Generator (N-G1,G2,G3), Load(N-L1,L2,L3), Main line(N-P1,P2,P3)
Dimensions in (mm):-
W-305, H-250, D-105

80 Amp. Three Phase (TPN)

Product code:- T-22
Working Voltage:- 415 V. 50hz.
Minimum operating voltage on generator supply:- 145 V. ± 4%
Connection Terminal:- 12-way. Generator (N-G1,G2,G3), Load(N-L1,L2,L3), Main line(N-P1,P2,P3)
Dimensions in (mm):-
W-305, H-250, D-105

100 Amp. Three Phase (TPN)

Product code:- T-23
Working Voltage:- 415 V. 50hz.
Minimum operating voltage on generator supply:- 145 V. ± 4%
Connection Terminal:- 12-way. Generator (N-G1,G2,G3), Load(N-L1,L2,L3), Main line(N-P1,P2,P3)
Dimensions in (mm):-
W-435, H-290, D105